Products >> JM 910 Anasthesia System
Features
- Integrated breathing circuit with APL valve, excellent tightness.
- Replacing drive bellow is NOT required when operating adult/pediatric anesthesia.
- Applied with 1 high-precision vaporizers (Selectatec).
- 10.1 inch screen with no dead space.
- Real-time detection for loops, Paw, BPM, VT and compliance.
- Comprehensive monitoring capabilities include ventilation parameters monitoring, preset parameters, alarm indication and breathing waveform monitoring.
- ACGO available to connect with T/Bain circuit for open operation.
- Yoke system with up to 3 back up cylinders (A type with 11L size).
Tecnique Specification
Physical specification |
|
Dimensions |
70*85*140cm |
Weight |
65kg. |
Casters |
Front wheels with lock |
Screen |
10.1 Inch LCD |
Working Specifications |
|
Power : |
AC 110V-240V, 50Hz±2% |
Pipeline Supply |
|
Gas configuration |
O2, N2O, Air (optional) |
Pipeline input range |
280-600kPa |
Battery Power |
|
Run time |
≥180 Mins |
Pre - Setting Functions |
|
Language |
English |
Calibration |
Automatic |
Application |
|
Patient Range |
Adult / Pediatric |
Ventilator Specifications |
|
Modes Of Ventilation |
|
VCV |
Volume Controlled Ventilation |
A/C |
Assist / Control Ventilation |
SIMV |
Synchronized Intermittent Mandatory Ventilation |
MANUAL |
Manual |
PCV |
Pressure Control Ventilation |
STAND-BY |
STAND-BY |
Ventilation Parameter |
|
Working type |
Electronically controlled, pneumatic driven |
Tidal Volume range |
20-1500 ml |
Pressure range |
5-60 cmH2O |
Rispriation rate range |
1-100 bpm (1-40 bpm under SIMV) |
I:E range |
4:1-1:8 |
Ptrigger range |
-20-20 cmH2O (Based on PEEP) |
Minute volume range |
> 18L/min |
SIGH range |
0-5/100 |
System standard |
|
Hypoxic guard system |
N2O cut-off valve, O2 Concentration >25% |
Safty valve |
< 12.5kPa |
Fresh Gas Compensation |
25 - 75L / min |
Volume of CO2 absorber |
2 L |
Flowmeter |
4 / 5 (Optional) tubes, Cascade 0.1 - 15L / min O2 |
0.1 - 15L / min N2O, 0.1 - 15L / min Air |
Vaporizer |
1 / 2 (Optional) selectatec, maximum 2 mounts (Isoflurane / Enflurane / Savoflurane / Halothane) |
Monitoring |
|
Display Graphics |
Waveforms of P-T, F-T, V-T, loops of P-V, V-F, F-P |
Types |
VT, MV, BPM, Paw, Lung Compliance, Inspiratory Platform, FiO2 |
Alarm Limits |
|
Audio / Visual |
No tidal volume, MV, Paw, FiO2 limitation O2 |
Air failure, AC power failure, battery low |
PEEP |
|
Type |
Integrated, Electronic control |
Range |
OFF, 3 - 30 cmH2O |
Optional |
|
1. AGSS |
|
2. Suction Unit |
|
3. Touch Screen |
|